Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the js_composer domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /home1/annap8xc/sivamedicalsystems.in/wp-includes/functions.php on line 6131

Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the woocommerce-accepted-payment-methods domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /home1/annap8xc/sivamedicalsystems.in/wp-includes/functions.php on line 6131

Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the woosidebars domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /home1/annap8xc/sivamedicalsystems.in/wp-includes/functions.php on line 6131

Warning: Cannot modify header information - headers already sent by (output started at /home1/annap8xc/sivamedicalsystems.in/wp-includes/functions.php:6131) in /home1/annap8xc/sivamedicalsystems.in/wp-includes/feed-rss2.php on line 8
Resipuff Archives - Siva Medical Systems https://sivamedicalsystems.in/product-category/neonatal-equipment/resipuff/ Guntur - Vizag - Rajahmundry - Tirupathi Thu, 27 Jan 2022 10:22:04 +0000 en-US hourly 1 https://wordpress.org/?v=6.9.4 https://sivamedicalsystems.in/wp-content/uploads/2021/09/icon-50x50.png Resipuff Archives - Siva Medical Systems https://sivamedicalsystems.in/product-category/neonatal-equipment/resipuff/ 32 32 Infant T-Piece Resuscitator Resipuff 1050 https://sivamedicalsystems.in/product/infant-t-piece-resuscitator-resipuff-1050/ Thu, 27 Jan 2022 10:19:25 +0000 https://sivamedicalsystems.in/?post_type=product&p=10964 infant T-Piece Resuscitator

Neokraft make Infant T-Piece Resuscitator is a lightweight standalone unit suitable for delivery wards, Neonatal care units, Operating rooms and Infant transport resuscitation purpose. With T-Piece resuscitator safely inflate the Baby’s lungs and provide optimum oxygenation by delivering consistent PIP & PEEP with each breath avoiding the risks associated with under or over inflation of uncontrolled pressures. T-Piece Resuscitator can connect to Neonatal masks or endotracheal tubes directly, to operate no battery or power is required.

MAX PRESSURE: - MAX Pressure relief valve to set maximum cut-off pressure where pressure will never deliver beyond set value

PIP: - Peak Inspiratory Pressure, PIP setting range from 5-75cm H20 [mbar]

Input flow 5 LPM Approx 5-70cm H20
Input flow 8 LPM Approx 6-75cm H20
Input flow 10 LPM Approx 8-75cm H20
Input flow 15 LPM Approx 10-75cm H20

PEEP: - Positive End Expiratory Pressure, PEEP Setting range from 2-25cm H20 [mbar]

Input flow 5 LPM Approx 2-5cm H20
Input flow 8 LPM Approx 4-8cm H20
Input flow 10 LPM Approx 4-10cm H20
Input flow 15 LPM Approx 6-20cm H20

Display: - Medical grade needle type monometer to monitor PIP & PEEP of each breath delivered

Monometer Display -20 to 100cm H20
Monometer Accuracy +/-2.0%
Maximum Pressure setting 40-80cm H2O
Factory Default Setting 40cm H2O Flow @ 6 LPM

*Accessories shown in the image may not be part of the standard equipment

The post Infant T-Piece Resuscitator Resipuff 1050 appeared first on Siva Medical Systems.

]]>
The post Infant T-Piece Resuscitator Resipuff 1050 appeared first on Siva Medical Systems.

]]>